OnCell 5004/5104 is an industrial cellular solution that supports GSM/GPRS cellular communication with multiple channel types and coding options. It also provides WAN and LAN interfaces, SIM control, and I/O interfaces. Additionally, the solution features network protocols, router/firewall capabilities, and security functions, and can be centrally managed through OnCell Central Mange.
This manual describes the OnCell 5004 and 5104 industrial‑grade cellular routers. Both models support four GSM/GPRS frequency bands (850/900/1800/1900 MHz), up to four 10/100 Mbps Ethernet ports, and optional VPN connectivity. The 5104 adds two isolated digital inputs and a 1 A @ 24 VDC relay output for alarm signaling.
Installation options include DIN‑rail or wall‑mounting, with a 12‑48 VDC power input and 1.5 kV Ethernet isolation. The document also lists mechanical dimensions, environmental limits, safety certifications, and ordering information. This manual is written in Chinese.
| Supported GSM/GPRS frequency bands | 850/900/1800/1900 MHz |
|---|---|
| Maximum Ethernet ports | 4 × 10/100 Mbps |
| Digital inputs (OnCell 5104) | 2 isolated inputs |
| Relay output (OnCell 5104) | 1 A @ 24 VDC |
| Power input voltage | 12‑48 VDC |
| Power consumption (OnCell 5004) | 400 mA typical, 900 mA max |
| Power consumption (OnCell 5104) | 450 mA typical, 950 mA max |
| Dimensions (OnCell 5004) | 158 × 103 × 35 mm |
| Dimensions (OnCell 5104) | 135 × 50.8 × 103 mm |
| Operating temperature range | -30 °C to 55 °C |
| Storage temperature range | -40 °C to 75 °C |
| Operating humidity range | 5 % to 95 % |
| Ingress protection rating | IP30 |
| Safety certification | UL 60950‑1 |
| Mean Time Between Failures (OnCell 5004) | 352,000 hours |
| Mean Time Between Failures (OnCell 5104) | 480,000 hours |
It supports the four GSM/GPRS bands 850 MHz, 900 MHz, 1800 MHz and 1900 MHz.
Each router provides up to four 10/100 Mbps Ethernet ports.
Yes, the OnCell 5104 includes one relay output rated at 1 A @ 24 VDC.
Both models accept a DC input of 12 V to 48 V, with typical currents of 400 mA (5004) or 450 mA (5104).