Seiko Instruments S-1000 Series Voltage Test Instrument Implementation Manual

The S-1000 series is a high-precision voltage detection IC developed using CMOS technology. It has a fixed internal detection voltage with an accuracy of ±1.0%. It features ultra-low power consumption and compact packaging, making it suitable for portable devices.


Seiko Instruments S-1000 Series Voltage Test Instrument Implementation Manual - cover page
Brand
SII
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
38
File format
PDF
File size
786 KB
Published
25 January, 2012
Updated
28 September, 2023
MD5 checksum
587A14DB22F15FB71795D1DAE24AA2B0

About this manual

The S-1000 series is a CMOS‑based voltage test IC offering ultra‑low power consumption (typical 350 nA) and high accuracy (±1.0 %). It supports a wide operating voltage range of 0.95 V to 5.5 V and provides a Vpp output of Vref + 1.5 V. The device is offered in three package types – SC‑82AB, SOT‑23‑5, and SNT‑4A – making it suitable for portable applications such as handheld devices, cameras, PDAs, and other compact electronics.

The manual includes pin‑out diagrams for each package, electrical characteristics tables, and guidelines for PCB layout and installation. It also details the two output modes (N‑channel MOSFET and CMOS) and provides recommended operating conditions, power‑dissipation limits, and temperature ranges. This manual is written in Chinese.

What's inside

  • Features
  • Applications
  • Package Options
  • Pin Configuration
  • Electrical Characteristics
  • Output Modes
  • Specifications
  • Installation Guidelines
  • Safety and Cautions

Specifications

Accuracy±1.0 %
Operating voltage range0.95 V – 5.5 V
Vpp outputVref + 1.5 V
Maximum output current50 mA
Operating temperature range-40 °C to +85 °C

Frequently asked questions

What accuracy does the S-1000 series provide?

It provides an accuracy of ±1.0 %.

Which package types are available for the S-1000 series?

The device is offered in SC‑82AB, SOT‑23‑5, and SNT‑4A packages.

What is the operating voltage range of the S-1000 series?

It operates from 0.95 V to 5.5 V.