This document provides operation and maintenance information for the Air Motor SM4AM. It includes important safety warnings and instructions on how to install, operate, inspect, and maintain the product. It emphasizes the use of clean, dry air and compliance with applicable standards and regulations. Additionally, it highlights the importance of using personal protective equipment.
This manual covers safe operation of the SM4AM air motor, including required personal protective equipment, emergency shut‑off valve placement, and the use of clean, dry air at the correct pressure. It also explains the meaning of safety symbols such as DANGER, WARNING, CAUTION and NOTICE.
Installation instructions recommend using a 1/2‑inch filter‑regulator‑lubricator (FRL) and provide line‑size guidelines. The motor’s vanes are made of a special material that does not require lubrication, though an FRL is suggested for optimal performance. Technical specifications such as power, speed, torque and air consumption are listed, and dimension drawings are provided for mounting.
| Maximum Power | 15 hp (1.1 kW) |
|---|---|
| Speed at Maximum Power | 3000 rpm |
| Free Speed | 700 rpm |
| Starting Torque | 26 (unit not specified) |
| Stall Torque | 35 (unit not specified) |
| Air Consumption at Max Power | 41 (unit not specified) |
| Weight | 67 kg |
| Recommended Air Pressure | 90 psig (6.2 bar / 620 kPa) |
Use clean, dry air at 90 psig (6.2 bar/620 kPa) as the maximum inlet pressure.
The SM4AM series vanes are made of a special material that does not require lubrication, though an air‑line lubricator is recommended for optimum performance.
A 1/2‑inch Filter‑Regulator‑Lubricator (FRL) is recommended for optimal motor performance and life.