SONIC EXCITER SX3040 user manual, introduces the product's usage methods, precautions and other information
This manual begins with important safety warnings and proper handling instructions for the Sonic Exciter SX3040. It explains how to power the unit, protect it from moisture, heat and electrical hazards, and describes the required grounding and fuse replacement procedures.
The guide then details the front‑panel controls and rear‑panel connectors, wiring configurations (series and parallel), installation into a 19‑inch rack, and a full set of technical data such as input/output impedance, frequency response and power consumption. Practical application examples for studio, live sound and stage use are also included. This manual is written in Chinese.
| Input Impedance | 20 kΩ balanced, 10 kΩ unbalanced |
|---|---|
| Rated Input Level | +4 dBu |
| Maximum Input Level | +22 dBu |
| Output Impedance | 60 Ω balanced, 60 Ω unbalanced |
| Maximum Output Level | +22 dBu |
| Frequency Response | 10 Hz – 120 kHz, ±3 dB |
| Signal‑to‑Noise Ratio | > 90 dB (20 Hz – 20 kHz) |
| Total Harmonic Distortion + Noise | 0.005 % |
| Power Consumption | ≈ 15 W |
| Dimensions (H × W × D) | 44.5 mm × 482.6 mm × 217 mm |
| Weight | ≈ 2.2 kg |
It can be powered from 120 V ~ 60 Hz (US/Canada) or 230 V ~ 50 Hz (Europe/UK/Australia) and other regional voltages.
Use a fuse of the same type and rating as the original.