Honeywell 40PC Pressure Sensor Manual


Honeywell 40PC Pressure Sensor Manual - cover page
Brand
Honeywell
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
190 KB
Published
13 November, 2011
Updated
29 September, 2023
Model
40PC
MD5 checksum
2E14782061E88EF7D48D760C5CE98B65

About this manual

This manual describes the Honeywell 40PC pressure sensor series, including its features, typical applications, and internal construction. It outlines the sensor's pressure ranges, output types, and environmental specifications.

The document also provides wiring diagrams, pin configurations, and installation dimensions, along with typical electrical characteristics such as supply voltage, output current, and sensitivity for various pressure ranges. This manual is written in Chinese.

What's inside

  • Features
  • Typical Applications
  • Internal Structure
  • Working Performance
  • Pressure Range
  • Output Signal
  • Supply Voltage
  • Temperature Range
  • Pin Configuration
  • Wiring Diagram

Specifications

Pressure range-0 to +500 mmHg, 0 to 15 psi, 0 to 100 psi, 0 to 250 psi, 0 to 500 psi, 0 to 1000 psi
Output type6‑pin DPT
Supply voltage5 VDC
Operating temperature-45 °C to +125 °C
Maximum output current10 mA max
Sensitivity (0‑100 psi)40.0 mV/psi (typical)
Accuracy (full scale)0.15 % FS (typical)

Frequently asked questions

What is the operating temperature range of the 40PC pressure sensor?

The sensor operates from –45 °C up to +125 °C.

What supply voltage does the 40PC sensor require?

It requires a 5 VDC supply.

What pressure ranges are covered by the 40PC series?

The series covers ranges from –0 to +500 mmHg (0 to 1000 psi) with specific models for 0‑15 psi, 0‑100 psi, 0‑250 psi, etc.

What is the typical output sensitivity for 0‑100 psi?

Typical sensitivity is 40.0 mV per psi.