Control Circuit Error 2 (Operator Transmission Error) means a 2 sec. + transmission error occurred after communication has been established between the controller and the operator after power ON or MPU peripheral element check error has occurred. The manual's first action is: “Re-connect operator and connector”
- Model
- YASKAWA VS-656DC5
- Display shows
- Control Circuit Error 2 (Operator Transmission Error) (CPF01)
- Type
- Error code
- Source
- Manual p. 21
What CPF01 means
Control Circuit Error 2 (Operator Transmission Error) p. 21
Common causes
- After communication has been established between the controller and the operator after power ON, a 2 sec. + transmission error occurred. p. 21
- MPU peripheral element check error p. 21
What to do
- Re-connect operator and connector p. 21
- Check wiring on control circuit power source p. 21
- Replace controller card p. 21
Before you service the product, read the safety instructions in the manual p. 5.
If CPF01 is still not resolved
- contact your YASKAWA representative p. 3 “To order a copy of this manual, contact your YASKAWA representative.”
This page summarises what the manufacturer’s manual says about CPF01; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.