Yaskawa Varispeed E7 CIMR-E7B Error 22H: Write Mode Error

Yaskawa Varispeed E7 CIMR-E7B inverter · taken from the manufacturer’s manual, pages cited

Warning code22H

Write Mode Error occurs when attempting to write parameters while the inverter is running, or when writing confirm command parameters while running, or when writing other parameters during an EEPROM fault. The manual lists no action for this code.

Model
Yaskawa Varispeed E7 CIMR-E7B
Display shows
Write Mode Error (22H)
Type
Warning code
Source
Manual p. 222

What 22H means

Write Mode Error p. 222

Common causes

  • Attempted to write parameters to the inverter while it was running. p. 222
  • Attempted to write confirm command parameters while running. p. 222
  • When warning alarm CPF03 (EEPROM fault) occurs, attempted to write parameters other than A1-00~05, E1-03, or O2-04. p. 222
  • Attempted to write read‑only data. p. 222

If 22H is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about 22H; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.