Fault codeA 8A2
Fully enclosed sequencer encoder sensor abnormality (incremental type) means a linear encoder fault. The manual's first action is: “Dynamic brake stop”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- A 8A2
- Type
- Fault code
- Source
- Manual p. 290
What A 8A2 means
Fully enclosed sequencer encoder sensor abnormality (incremental type) p. 290
Common causes
What to do
Before you service the product, read the safety instructions in the manual p. 292.
If A 8A2 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A 8A2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.