This code means heatsink overheat (thermistor temperature too high) due to ambient temperature too high, fan damaged, or air duct blocked. The manual's first action is: “Lower ambient temperature”
- Model
- Xinling XLP3200T
- Display shows
- Heatsink overheat (thermistor temperature too high) (OH.1)
- Type
- Error code
- Source
- Manual p. 50
What OH.1 means
Heatsink overheat (thermistor temperature too high) p. 50
Common causes
- Ambient temperature too high p. 50
- Fan damaged p. 50
- Air duct blocked p. 50
- V/F curve unsuitable p. 50
What to do
- Lower ambient temperature p. 50
- Replace fan p. 50
- Clear air duct p. 50
- Adjust V/F curve and torque boost amount p. 50
Before you service the product, read the safety instructions in the manual p. 3.
If OH.1 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Xinling service.
This page summarises what the manufacturer’s manual says about OH.1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Xinling. Found a mistake? Report an error.