WEG CFW-11 Error A134: Bus Off

Frequency inverter · taken from the manufacturer’s manual, pages cited

Fault codeA134

Bus Off means incorrect communication baud-rate, two nodes configured with the same address in the network, or wrong cable connection (inverted signals) caused a bus off. The manual lists no action for this code.

Model
WEG CFW-11
Display shows
Bus Off (A134)
Type
Fault code
Source
Manual p. 67

What A134 means

Bus Off p. 67

Common causes

  • Incorrect communication baud-rate. p. 67
  • Two nodes configured with the same address in the network. p. 67
  • Wrong cable connection (inverted signals). p. 67

If A134 is still not resolved

  • contact WEG p. 7
    “If needed, please, consult WEG.”