Viessmann Vitodens 111-W Error 544: Emergency function operating mode is activated for heating circuit 2: Mixer closes. Heating circuit pump is operational.

Viessmann Vitodens 111-W water heater · taken from the manufacturer’s manual, pages cited

Fault code544

Emergency function is activated for heating circuit 2 due to lead break, flow temperature sensor, or incorrect setting during commissioning. The manual's first action is: “Check flow temperature sensor, mixer 2. Measure voltage at sensor input on electronics module. Set value: 3.3 V– with sensor disconnected. Check setting in the commissioning assistant and correct if required. Checking setting of ADIO rotary switch.”

Model
Viessmann Vitodens 111-W
Display shows
544
Type
Fault code
Source
Manual p. 82

What 544 means

Emergency function operating mode is activated for heating circuit 2: Mixer closes. Heating circuit pump is operational. p. 82

Common causes

  • Lead break, flow temperature sensor, heating circuit 2 with mixer Incorrect setting during commissioning p. 82

What to do

  1. Check flow temperature sensor, mixer 2. Measure voltage at sensor input on electronics module. Set value: 3.3 V– with sensor disconnected. Check setting in the commissioning assistant and correct if required. Checking setting of ADIO rotary switch. p. 82

If 544 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Viessmann service.

This page summarises what the manufacturer’s manual says about 544; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Viessmann. Found a mistake? Report an error.