Fault 182 means no DHW heating because there is a short circuit in the outlet temperature sensor (if installed). The manual's first action is: “Check outlet temperature sensor (plug X7, cores 3 and 4). Measure sensor input on HBMU heat management unit. Set value: 3.3 V– with sensor disconnected”
- Model
- Viessmann Vitodens 111-W
- Display shows
- No DHW heating (182)
- Type
- Fault code
- Source
- Manual p. 72
What 182 means
No DHW heating p. 72
Common causes
- Short circuit, outlet temperature sensor (if installed) p. 72
What to do
- Check outlet temperature sensor (plug X7, cores 3 and 4). Measure sensor input on HBMU heat management unit. Set value: 3.3 V– with sensor disconnected p. 72
If 182 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Viessmann service.
This page summarises what the manufacturer’s manual says about 182; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Viessmann. Found a mistake? Report an error.