Taian Technology S310-201-H1BCD Error STP2: Keyboard emergency stop

Motor driver · taken from the manufacturer’s manual, pages cited

Error codeSTP2

Keyboard emergency stop means pressing the STOP key on the keyboard during operation causes the inverter to stop according to the setting, or after stopping, STP2 flashes. The manual lists no action for this code.

Model
Taian Technology S310-201-H1BCD
Display shows
Keyboard emergency stop (STP2)
Type
Error code
Source
Manual p. 47

What STP2 means

Keyboard emergency stop p. 47

Common causes

  • When the inverter is set for external operation (00‑03=1) and the STOP key is enabled, pressing the STOP key on the keyboard during operation causes the inverter to stop according to the setting in 04‑01; after stopping, STP2 flashes, and the run switch must be turned OFF and then ON again before it can restart. p. 47
  • If the inverter is in communication mode and the STOP key is enabled, pressing the STOP key on the keyboard during operation stops the inverter according to 04‑01; after stopping, STP2 flashes, and the PC must first send a STOP command followed by a run command to the inverter before it can restart. p. 47

If STP2 is still not resolved

  • Contact Taian Technology regional dealers or company technical personnel for difficult problems. p. 5
    “当您在使用过程中发现疑难问题时,请与台安科技各地区经销商或本公司技术人员 联系”

This page summarises what the manufacturer’s manual says about STP2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Taian Technology. Found a mistake? Report an error.