SMC IZT40, IZT41/42 series Error E4: Communication error

Ionizer · taken from the manufacturer’s manual, pages cited

Error codeE4

Communication error happens due to power supply +24 VDC OFF, controller button ▲ / ▼ / S button OFF, or a communication issue. The manual's first action is: “Turn the power off and on again”

Model
SMC IZT40, IZT41/42 series
Display shows
Communication error (E4)
Type
Error code
Source
Manual p. 40

What E4 means

Communication error p. 59

Common causes

  • Power supply +24 VDC OFF p. 59
  • Controller button ▲ / ▼ / S button OFF p. 59
  • Communication error p. 59
  • When communication failure occurs due to noise or disconnection, etc. p. 59
  • Communication error (applicable models: IZT40, IZT41, IZT42). When abnormality occurs in the communication between the controller and high voltage power supply module due to electrical noise or disconnection. p. 59

What to do

  1. Turn the power off and on again p. 59
  2. The abnormal signal is OFF (ON when normal. IZTC40 does not have an output signal), and the ION/HV LED of CH with abnormality is flashing (red) and the error code "E4" is flashing in the frequency display. p. 59

If E4 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact SMC service.