No dial tone The manual's first action is: “The LED lights to indicate an error condition. This error occurs only if the EM241 is configured to check for a dial tone before dialing. After a dialing attempt fails, the LED turns on and stays on for about 5 seconds.”
- Model
- Siemens S7-200
- Display shows
- No dial tone (NT)
- Type
- Error code
- Source
- Manual p. 301
What NT means
No dial tone p. 301
Common causes
- When the EM241 receives a send-message command but there is no dial tone on the telephone line p. 301
What to do
- The LED lights to indicate an error condition. This error occurs only if the EM241 is configured to check for a dial tone before dialing. After a dialing attempt fails, the LED turns on and stays on for about 5 seconds. p. 301
Before you service the product, read the safety instructions in the manual p. 2.
If NT is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about NT; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.