A0580 on the Siemens MICROMASTER 440 is listed in the manual as: Encoder feedback signal loss alarm. The manual's first action is: “Stop the inverter, then: 1. Check the encoder installation. If no encoder is installed, set 0400 = 0 and select the SLVC operating mode (P1300 = 20 or 22). 2. Check the wiring between the inverter and the encoder. 3. Verify that the encoder is fault‑free (select P1300 = 0, run the inverter at a fixed speed, and check the encoder feedback signal in P0066). 4. Increase the encoder‑signal‑loss threshold (P0492).”
- Model
- Siemens MICROMASTER 440
- Display shows
- Encoder feedback signal loss alarm (A0580)
- Type
- Alarm code
- Source
- Manual p. 100
What A0580 means
Encoder feedback signal loss alarm p. 100
Common causes
- Feedback signal from the encoder is lost, causing the inverter to switch to sensorless vector control mode. p. 100
What to do
- Stop the inverter, then: 1. Check the encoder installation. If no encoder is installed, set 0400 = 0 and select the SLVC operating mode (P1300 = 20 or 22). 2. Check the wiring between the inverter and the encoder. 3. Verify that the encoder is fault‑free (select P1300 = 0, run the inverter at a fixed speed, and check the encoder feedback signal in P0066). 4. Increase the encoder‑signal‑loss threshold (P0492). p. 100
Before you service the product, read the safety instructions in the manual p. 7.
If A0580 is still not resolved
This page summarises what the manufacturer’s manual says about A0580; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.