Schneider Electric Altivar 71W Error LCF: [LINE CONTACT. FAULT]

Variable speed drive · taken from the manufacturer’s manual, pages cited

Fault codeLCF

LCF indicates the drive is not powering up although the contactor is controlled. The manual's first action is: “Check the contactor and its wiring”

Model
Schneider Electric Altivar 71W
Display shows
[LINE CONTACT. FAULT] (LCF)
Type
Fault code
Source
Manual p. 72

What LCF means

[LINE CONTACT. FAULT] p. 72

Common causes

  • The drive is not powering up although the contactor is controlled. p. 72

What to do

  1. Check the contactor and its wiring p. 72
  2. Check the time-out (consult the CD-ROM supplied with the drive) p. 72
  3. Check the mains/contactor/drive wiring p. 72

Before you service the product, read the safety instructions in the manual p. 41.

If LCF is still not resolved

  • contact Schneider Electric service p. 42
    “Failure to follow these instructions will result in death, serious physical injury or equipment damage.”

This page summarises what the manufacturer’s manual says about LCF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.