Schneider Electric Altivar 71W Error BLF: [BRAKE CONTROL FAULT]

Variable speed drive · taken from the manufacturer’s manual, pages cited

Fault codeBLF

Brake release current not reached or brake control parameters not set when brake logic control is assigned The manual's first action is: “Check the drive/motor connection”

Model
Schneider Electric Altivar 71W
Display shows
[BRAKE CONTROL FAULT] (BLF)
Type
Fault code
Source
Manual p. 72

What BLF means

[BRAKE CONTROL FAULT] p. 72

Common causes

  • Brake release current not reached p. 72
  • Brake control parameters not set when brake logic control is assigned p. 72

What to do

  1. Check the drive/motor connection p. 72
  2. Check the motor windings p. 72
  3. Apply the recommended settings (consult the CD-ROM supplied with the drive) p. 72

Before you service the product, read the safety instructions in the manual p. 41.

If BLF is still not resolved

  • contact Schneider Electric service p. 42
    “Failure to follow these instructions will result in death, serious physical injury or equipment damage.”

This page summarises what the manufacturer’s manual says about BLF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.