The encoder speed feedback does not match the reference The manual's first action is: “Check the motor, gain and stability parameters Add a braking resistor Check the size of the motor/drive/load Check the encoder's mechanical coupling and its wiring.”
- Model
- Schneider Electric Altivar 71W/E5
- Display shows
- [LOAD SLIPPING] (RnF)
- Type
- Fault code
- Source
- Manual p. 75
What RnF means
[LOAD SLIPPING] p. 75
Common causes
- The encoder speed feedback does not match the reference p. 75
What to do
- Check the motor, gain and stability parameters Add a braking resistor Check the size of the motor/drive/load Check the encoder's mechanical coupling and its wiring. p. 75
Before you service the product, read the safety instructions in the manual p. 43.
If RnF is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.
This page summarises what the manufacturer’s manual says about RnF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.