Schneider Electric Altivar 61W Error ObF: [Overbraking]

Altivar 61W drive · taken from the manufacturer’s manual, pages cited

Fault codeObF

The ObF code indicates Overbraking caused by braking too sudden or driving load. The manual's first action is: “Increase the deceleration time Install a braking resistor if necessary Activate the [Déc ramp adapt.] (brA) function (consult the CD-ROM supplied with the drive), if it is compatible with the application”

Model
Schneider Electric Altivar 61W
Display shows
[Overbraking] (ObF)
Type
Fault code
Source
Manual p. 77

What ObF means

[Overbraking] p. 77

Common causes

  • Braking too sudden or driving load p. 77

What to do

  1. Increase the deceleration time Install a braking resistor if necessary Activate the [Déc ramp adapt.] (brA) function (consult the CD-ROM supplied with the drive), if it is compatible with the application p. 77

Before you service the product, read the safety instructions in the manual p. 43.

If ObF is still not resolved

  • Disconnect all power including external control power p. 44
    “Disconnect all power including external control power that may be present before servicing the drive.”

This page summarises what the manufacturer’s manual says about ObF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.