Schneider Electric Altivar 61W Error bDF: [DBR overload]

Altivar 61W drive · taken from the manufacturer’s manual, pages cited

Fault codebDF

The braking resistor is under excessive stress means the resistor is being overloaded and may overheat. The manual's first action is: “Check the size of the resistor and wait for it to cool down.”

Model
Schneider Electric Altivar 61W
Display shows
[DBR overload] (bDF)
Type
Fault code
Source
Manual p. 75

What bDF means

[DBR overload] p. 75

Common causes

  • The braking resistor is under excessive stress. p. 75

What to do

  1. Check the size of the resistor and wait for it to cool down. p. 75
  2. Check parameters [DB Resistor Power] (brP) and [DB Resistor value] (brL) (consult the CD-ROM supplied with the drive). p. 75

Before you service the product, read the safety instructions in the manual p. 43.

If bDF is still not resolved

  • Disconnect all power including external control power p. 44
    “Disconnect all power including external control power that may be present before servicing the drive.”

This page summarises what the manufacturer’s manual says about bDF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.