Fault codeOP3
Past fault 3 indicates the input voltage is fluctuating abnormally, the power network is greater than 200 kVA, or power factor capacitor switching occurred. The manual's first action is: “Third most recent fault.”
- Model
- Schneider Electric Altivar 21
- Display shows
- Past fault 3 (OP3)
- Type
- Fault code
- Source
- Manual p. 17
What OP3 means
Past fault 3 p. 17
Common causes
- The input voltage is fluctuating abnormally. p. 17
- Power network is greater than 200 kVA p. 17
- Power factor capacitor switching p. 17
- SCR switching on power network p. 17
- The drive is regenerating - the load causes the motor to run at a frequency higher than drive output frequency. p. 17
- Intermittent output phase fault p. 17
What to do
- Third most recent fault. p. 17
- Install a line reactor. p. 17
- Check the input and output circuits for phase failure and rectify. p. 17
Before you service the product, read the safety instructions in the manual p. 5.
If OP3 is still not resolved
This page summarises what the manufacturer’s manual says about OP3; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.