Motor short circuit means short-circuit at drive output. The manual's first action is: “Check the cables connecting the drive to the motor, and the motor's insulation”
- Model
- Schneider Altivar 61
- Display shows
- [Motor short circuit] (SCF5)
- Type
- Fault code
- Source
- Manual p. 244
What SCF5 means
[Motor short circuit] p. 244
Common causes
- Short-circuit at drive output p. 244
What to do
- Check the cables connecting the drive to the motor, and the motor's insulation p. 244
- Perform tests via the [1.10 DIAGNOSTICS] menu. Inspect/repair the drive p. 244
Before you service the product, read the safety instructions in the manual p. 10.
If SCF5 is still not resolved
- Disconnect all power including external control power p. 4 “Disconnect all power including external control power that may be present before servicing the drive.”
This page summarises what the manufacturer’s manual says about SCF5; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider. Found a mistake? Report an error.