Sanyo Machine Works SDNR Error A3: PROGRAM END ERROR

AC Servo Nutrunner · taken from the manufacturer’s manual, pages cited

Error codeA3

The program has ended unexpectedly due to an incorrect system setting. The manual's first action is: “Add an end of cycle command to the end of the fastening program.”

Model
Sanyo Machine Works SDNR
Display shows
PROGRAM END ERROR (A3)
Type
Error code
Source
Manual p. 104

What A3 means

PROGRAM END ERROR p. 128

Common causes

  • System setting is wrong. p. 128

What to do

  1. Add an end of cycle command to the end of the fastening program. p. 128

Before you service the product, read the safety instructions in the manual p. 65.

If A3 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Sanyo Machine Works service.

This page summarises what the manufacturer’s manual says about A3; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Sanyo Machine Works. Found a mistake? Report an error.