LANCE SIR NI interrupt register bit not set during PATT 3: Color bar reference voltage test. The manual lists no action for this code.
Single-bit error occurred in a field of 0's, LANCE TC interrupt register bit not set, or SCC I/K401 test received illegal response during PATT 2: Color bar test. The manual's first action is: “Memory module”
Single-bit error occurred in a field of 1's, LANCE interrupts failed to initialize, or SCC I/K401 test timed out during PATT 1: Fill video RAM. The manual's first action is: “Memory module”
Network address ROM has bad group 2 during VDAC 13: Cursor signature test. The manual's first action is: “System module”
SCSI minimal device test failed for bus A during VDAC 7: Load color map. The manual's first action is: “System module”
SCSI map error test failed for bus A during VDAC 6: Overlay RAM test. The manual's first action is: “System module”
Parity error machine check occurred, or data miscompare happened during CORE I/O ASIC register testing including Ethernet DMA Ptr, awaiting user input at SROM> prompt. The manual's first action is: “System module”
Console code cannot execute because NoBoot jumper is installed, PSHIFT 1 test passes, or LANCE initialization fails while SRROM code executes normally. The manual's first action is: “System module”
I/O ROM header read failed due to unexpected data, PSHIFT 1 test failure, or LANCE transmit failure during loading I/O ROM contents into memory. The manual's first action is: “System module”
SYSROM manufacturing data read failed due to I/O space access error or corrupted SYSROM, or LANCE unknown transmit error occurs while fetching SYSROM header. The manual lists no action for this code.
Error in system interrupt register or LANCE receive failure occurs during CORE I/O register test and initialization. The manual lists no action for this code.
All 64 error codes of the Digital Equipment Corporation DEC 3000 Model 300 Series AXP DEC 3000 Model 300 Series AXP system with their meaning, causes and what to do, taken from the manufacturer's manual with page refe…
Other Error indicates an undefined error condition has occurred. The manual lists no action for this code.
Buffer Overrun occurs when a node sends more data than expected or the gateway can’t process messages fast enough. The manual lists no action for this code.
Multiple Nodes Missing indicates multiple nodes are offline or timed out consume-transactions have accumulated. The manual's first action is: “See also.. - "Consume Transactions" on page 33 (Offline timeout time)”