Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
CH□ Scaling upper limit value and CH□ Scaling lower limit value are equal. The manual's first action is: “Reset CH□ Scaling upper limit value or CH□ scaling lower limit value such that Scaling upper limit value=Scalin…
A value other than 1 to 10000 was set to CH□ rate alarm warning detection period setting. The manual's first action is: “Reset the CH□ rate alarm warning detection period setting to the value within 1 to 10000.”
Lower limit value≥upper limit value was set to CH□ rate alarm upper limit value and CH□ rate alarm lower limit value. The manual's first action is: “Reset CH□ rate alarm upper limit value and CH□ rate alarm lower limi…
The value not meeting the following conditions was set to CH□ process alarm upper-upper limit value to CH□ process alarm lower-lower limit value. The manual's first action is: “Reset CH□ process alarm upper-upper limi…
When the moving average is set to CH□ Averaging process specification, the following value was set to CH□ moving average count setting. The manual's first action is: “Reset CH□ moving average process setting to the fo…
When the count average is set to CH□ Averaging process specification, a value other than 4 to 32767 was set to CH□ time average/ count average/moving average settings. The manual's first action is: “Reset CH□ time ave…
When the time average is set to CH□ Averaging process specification, a value other than 1 to 10000 was set to CH□ time average/ count average/moving average settings. The manual's first action is: “Reset CH□ time aver…
A value other than 0 to 3 was set in CH□ Averaging process specification. The manual's first action is: “Reset CH□ the Averaging process specification to 0 to 3.”
There is no error. The manual lists no action for this code.
All 11 error codes of the Mitsubishi Electric FX5 PLC with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
Motor or controller has short circuit Abnormality means there is a short circuit detected in either the motor or its controller. The manual lists no action for this code.
Axis speed sensor Abnormality(only applied to torque sensor ) indicates a problem with the speed sensor linked to the torque sensor. The manual lists no action for this code.
Torque sensor Signal Abnormality shows that the torque measurement sensor is sending incorrect data. The manual lists no action for this code.
Motor Hall Signal Abnormality means the motor's position sensor signals are not functioning correctly. The manual lists no action for this code.
Throttle Abnormality indicates an issue with the throttle input or signal. The manual lists no action for this code.