Omron R88D-WT Error A.E7: Optional unit detection error

AC servo driver · taken from the manufacturer’s manual, pages cited

Error codeA.E7

An optional unit detection error occurs when power is turned on after removing an optional unit or after an A.E7 alarm occurs. The manual's first action is: “An A.E7 alarm (optional unit detection error) will occur. This is because the servo drive determines an error when it does not detect the optional unit.”

Model
Omron R88D-WT
Display shows
Optional unit detection error (A.E7)
Type
Error code
Source
Manual p. 384

What A.E7 means

Optional unit detection error p. 384

Common causes

  • When power is turned on after removing an optional unit p. 384
  • After an A.E7 alarm occurs p. 384

What to do

  1. An A.E7 alarm (optional unit detection error) will occur. This is because the servo drive determines an error when it does not detect the optional unit. p. 384
  2. It can be cleared using one of the methods below. p. 384

Before you service the product, read the safety instructions in the manual p. 389.

If A.E7 is still not resolved

  • contact OMRON service or dealer p. 2
    “不注意这些事项可能导致对人体的伤害或危及财产”
  • contact OMRON service or dealer p. 389
    “相应的报警对应措施,见5-3-1用报警显示进行错误诊断”

This page summarises what the manufacturer’s manual says about A.E7; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.