Omron R88D-WT Error A.d0: Excessive deviation counter overflow

AC servo driver · taken from the manufacturer’s manual, pages cited

Error codeA.d0

The A.d0 code indicates excessive deviation counter overflow, which can be caused by deviation counter overflow, the servo motor not rotating even when command pulses are input, or a mechanical lock. The manual's first action is: “Remaining pulses in the deviation counter exceed the overflow level set in Pn505.”

Model
Omron R88D-WT
Display shows
Excessive deviation counter overflow (A.d0)
Type
Error code
Source
Manual p. 390

What A.d0 means

Excessive deviation counter overflow p. 390

Common causes

  • Deviation counter overflow p. 390
  • Servo motor does not rotate even when command pulses are input. p. 390
  • Mechanical lock p. 390
  • Control panel error p. 390
  • Occurs during high-speed rotation. p. 390
  • Insufficient gain adjustment. p. 390
  • Excessive acceleration/deceleration. p. 390
  • Overload. p. 390

What to do

  1. Remaining pulses in the deviation counter exceed the overflow level set in Pn505. p. 390
  2. Servo motor power or encoder wiring is incorrect. Rewire correctly. p. 390
  3. If the servo motor shaft is locked, repair it. p. 390
  4. Replace the servo drive. p. 390
  5. Adjust the gain. p. 390
  6. Extend acceleration/deceleration time. Use position command filters (Pn207.0, Pn204, and Pn208). p. 390
  7. Reduce the load. Select a different servo motor. p. 390

Before you service the product, read the safety instructions in the manual p. 389.

If A.d0 is still not resolved

  • contact OMRON service or dealer p. 2
    “不注意这些事项可能导致对人体的伤害或危及财产”
  • contact OMRON service or dealer p. 389
    “相应的报警对应措施,见5-3-1用报警显示进行错误诊断”

This page summarises what the manufacturer’s manual says about A.d0; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.