The setting of Pn001.2 (AC/DC input selection) does not match the AC/DC wiring method of the main loop power, indicating a main loop power setting error. The manual's first action is: “The setting of Pn001.2 (AC/DC input selection) does not match the AC/DC wiring method of the main loop power.”
- Model
- Omron R88D-WT
- Display shows
- Main loop power setting error (see note 3) (A.33)
- Type
- Error code
- Source
- Manual p. 390
What A.33 means
Main loop power setting error (see note 3) p. 390
Common causes
- Main loop power setting error (see note 3) p. 390
What to do
- The setting of Pn001.2 (AC/DC input selection) does not match the AC/DC wiring method of the main loop power. p. 390
Before you service the product, read the safety instructions in the manual p. 389.
If A.33 is still not resolved
This page summarises what the manufacturer’s manual says about A.33; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.