Motor mismatch occurs when the servo motor and drive are not matched or the encoder cable is broken. The manual's first action is: “· Motor/drive combination mismatch · Correct the combination”
- Model
- Omron OMNUC G
- Display shows
- Motor mismatch (95)
- Type
- Error code
- Source
- Manual p. 343
What 95 means
Motor mismatch p. 409
Common causes
- Servo motor and drive are not matched. Encoder not connected when power is applied. p. 409
- Occurs when power is applied. p. 409
- · Encoder cable is broken p. 409
What to do
- · Motor/drive combination mismatch · Correct the combination p. 409
- · Rewire encoder cable · Repair the broken section p. 409
Before you service the product, read the safety instructions in the manual p. 273.
If 95 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.