Analog input too large 2 occurs when the current in the analog command input exceeds the overflow level set by parameter Pn71 during operation. The manual's first action is: “Possible”
- Model
- Omron OMNUC G
- Display shows
- Analog input too large 2 (65)
- Type
- Error code
- Source
- Manual p. 343
What 65 means
Analog input too large 2 p. 403
Common causes
- The current flowing in the analog command input (CN, pin 16) exceeds the overflow level set by parameter Pn71 for speed/torque command input. p. 403
- Occurs during operation. p. 403
What to do
- Possible p. 403
- · Voltage to pin 16 is too high · Reduce input voltage · Change the value of Pn71 p. 403
Before you service the product, read the safety instructions in the manual p. 273.
If 65 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.