NORDAC SK 500E / SK 520E Error E016.1: Motor current control response during brake operation

NORDAC SK 500E / SK 520E inverter · taken from the manufacturer’s manual, pages cited

Error codeE016.1

Motor current control response during brake operation failure The manual's first action is: “Check setting of P539”

Model
NORDAC SK 500E / SK 520E
Display shows
Motor current control response during brake operation (E016.1)
Type
Error code
Source
Manual p. 17

What E016.1 means

Motor current control response during brake operation p. 17

Common causes

  • Failure to ensure the magnetization current required at the moment of brake release p. 17

Safety warnings — read before you start

  • DANGERDANGER. touching them may cause, due to the voltages at which they are operated, serious injuries or even death p. 1

What to do

  1. Check setting of P539 p. 17
  2. Check whether the motor is properly connected p. 17

If E016.1 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact NORDAC service.

This page summarises what the manufacturer’s manual says about E016.1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with NORDAC. Found a mistake? Report an error.