Error codeE002
The motor has overheated due to the PTC resistor triggering. The manual's first action is: “Reduce load on the motor”
- Model
- NORDAC SK 500E / SK 520E
- Display shows
- Motor overtemperature (PTC resistor) (E002)
- Type
- Error code
- Source
- Manual p. 15
What E002 means
Motor overtemperature (PTC resistor) p. 15
Common causes
- The motor temperature sensor has picked up. p. 15
- Disconnection at I²t motor temperature limit p. 15
Safety warnings — read before you start
- DANGERDANGER. Touching them may cause, due to the voltages at which they are operated, serious injuries or even death. p. 1
What to do
- Reduce load on the motor p. 15
- Increase motor speed p. 15
- Provide motor with separate ventilation p. 15
If E002 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact NORDAC service.
This page summarises what the manufacturer’s manual says about E002; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with NORDAC. Found a mistake? Report an error.