Mitsubishi MR‑E‑AG Error AL.10: Undervoltage

Servo amplifier · taken from the manufacturer’s manual, pages cited

Error codeAL.10

The Undervoltage code indicates the power supply voltage is low, a momentary loss of control power lasting more than 60 ms occurs, or power supply voltage drops during start-up due to insufficient power supply capacity. The manual's first action is: “Reassess the power supply.”

Model
Mitsubishi MR‑E‑AG
Display shows
Undervoltage (AL.10)
Type
Error code
Source
Manual p. 77

What AL.10 means

Undervoltage p. 77

Common causes

  • Power supply voltage is low. p. 77
  • A momentary loss of the control power lasting more than 60 ms occurs. p. 77
  • Power supply voltage drops during start-up due to insufficient power supply capacity. p. 77
  • Bus voltage fell to DC 200 V and then recovered (main power reconnected within 5 s after interruption). p. 77
  • Component failure inside the intermittent amplifier. p. 77
  • Refer to the replacement procedure. p. 77

What to do

  1. Reassess the power supply. p. 77
  2. Replace the intermittent amplifier. p. 77
  3. Then follow these steps: disconnect all circuits except the power supply and turn on the power supply. See Appendix 3A... p. 77

Before you service the product, read the safety instructions in the manual p. 4.

If AL.10 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Mitsubishi service.

This page summarises what the manufacturer’s manual says about AL.10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi. Found a mistake? Report an error.