Mitsubishi Electric MR-J2S-A Error Y4A: ABS data check sum error

Servo amplifier and motor · taken from the manufacturer’s manual, pages cited

Error codeY4A

1. Wiring for the ABS data signal (ABS bit 0 (PF), bit 1 (ZSP)) is disconnected or connected to the SG terminal., 2. PC ladder program wrong., 3. Faulty PLC input module. The manual's first action is: “Correct the wiring.”

Model
Mitsubishi Electric MR-J2S-A
Display shows
ABS data check sum error (Y4A)
Type
Error code
Source
Manual p. 371

What Y4A means

ABS data check sum error p. 371

Common causes

  • 1. Wiring for the ABS data signal (ABS bit 0 (PF), bit 1 (ZSP)) is disconnected or connected to the SG terminal. p. 371
  • 2. PC ladder program wrong. p. 371
  • 3. Faulty PLC input module. p. 371
  • 4. Faulty printed board in the servo amplifier. p. 371

What to do

  1. Correct the wiring. p. 371
  2. Correct the ladder. p. 371
  3. Change the input module. p. 371
  4. Change the amplifier. p. 371

Before you service the product, read the safety instructions in the manual p. 3.

If Y4A is still not resolved

  • contact service / dealer p. 3
    “Do not attempt to install, operate, maintain or inspect the servo amplifier and servo motor until you have read through this Instruction Manual, Installation guide, Servo motor Instruction Manual and appended documents carefully and can use the equipment correctly.”
  • contact service / dealer p. 4
    “Do not attempt to wire the servo amplifier and servo motor until they have been installed. Otherwise, you may get an electric shock.”

This page summarises what the manufacturer’s manual says about Y4A; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.