Mitsubishi Electric MR-J2S-A Error AL.E5: ABS time-out warning

Servo amplifier and motor · taken from the manufacturer’s manual, pages cited

Alarm codeAL.E5

ABS time-out warning occurs if the PC ladder program is wrong or reverse rotation start (ST2) with improper limiting torque (TLC) wiring. The manual's first action is: “Power OFF→ON”

Model
Mitsubishi Electric MR-J2S-A
Display shows
ABS time-out warning (AL.E5)
Type
Alarm code
Source
Manual p. 200

What AL.E5 means

ABS time-out warning p. 200

Common causes

  • 1. PC ladder program wrong. p. 200
  • 2. Reverse rotation start (ST2) * Limiting torque (TLC) improper wiring p. 200

What to do

  1. Power OFF→ON p. 200
  2. Press "SET" on current alarm screen. p. 200
  3. Alarm reset (RES) p. 200
  4. Contact the program. p. 200
  5. Connect properly. p. 200

Before you service the product, read the safety instructions in the manual p. 3.

If AL.E5 is still not resolved

  • contact service / dealer p. 3
    “Do not attempt to install, operate, maintain or inspect the servo amplifier and servo motor until you have read through this Instruction Manual, Installation guide, Servo motor Instruction Manual and appended documents carefully and can use the equipment correctly.”
  • contact service / dealer p. 4
    “Do not attempt to wire the servo amplifier and servo motor until they have been installed. Otherwise, you may get an electric shock.”

This page summarises what the manufacturer’s manual says about AL.E5; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.