Alarm codeAL.45
Main circuit device alarm indicates servo amplifier fault, continuous power cycling under overload, or fan failure in the servo amplifier. The manual's first action is: “Power OFF→ON”
- Model
- Mitsubishi Electric MR-J2S-A
- Display shows
- Main circuit device (AL.45)
- Type
- Alarm code
- Source
- Manual p. 69
What AL.45 means
Main circuit device p. 200
Common causes
- 1. Servo amplifier faulty. p. 200
- 2. The power supply was turned on and off continuously by overloaded status. p. 200
- 3. Air cooling fan of servo amplifier stops. p. 200
What to do
- Power OFF→ON p. 200
- Press "SET" on current alarm screen. p. 200
- Alarm reset (RES) p. 200
- Change the servo amplifier. p. 200
- The drive method is reviewed. p. 200
- 1. Exchange the cooling fan or the servo amplifier. 2. Reduce ambient temperature. p. 200
Before you service the product, read the safety instructions in the manual p. 3.
If AL.45 is still not resolved
- contact service / dealer p. 3 “Do not attempt to install, operate, maintain or inspect the servo amplifier and servo motor until you have read through this Instruction Manual, Installation guide, Servo motor Instruction Manual and appended documents carefully and can use the equipment correctly.”
- contact service / dealer p. 4 “Do not attempt to wire the servo amplifier and servo motor until they have been installed. Otherwise, you may get an electric shock.”
This page summarises what the manufacturer’s manual says about AL.45; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.