Mitsubishi Electric MR-J2S-A Error AL.17: Board error

Servo amplifier and motor · taken from the manufacturer’s manual, pages cited

Alarm codeAL.17

Board error occurs when servo amplifier components are faulty or motor and amplifier terminals are not properly connected. The manual's first action is: “Power OFF→ON”

Model
Mitsubishi Electric MR-J2S-A
Display shows
Board error (AL.17)
Type
Alarm code
Source
Manual p. 69

What AL.17 means

Board error p. 200

Common causes

  • 1. Faulty parts in the servo amplifier. Checking method Alarm (AL.17) occurs if power is switched on after disconnection of a ll cable but the control circuit power supply cable. p. 200
  • The output terminals U, V, W of the servo amplifier and the input terminals U, V, W of the servo motor are not connected. p. 200

What to do

  1. Power OFF→ON p. 200
  2. Press "SET" on current alarm screen. p. 200
  3. Alarm reset (RES) p. 200
  4. Change the servo amplifier. p. 200
  5. Correctly connect the output terminals U, V, W of the servo amplifier and the input terminals U, V, W of the servo motor. p. 200

Before you service the product, read the safety instructions in the manual p. 3.

If AL.17 is still not resolved

  • contact service / dealer p. 3
    “Do not attempt to install, operate, maintain or inspect the servo amplifier and servo motor until you have read through this Instruction Manual, Installation guide, Servo motor Instruction Manual and appended documents carefully and can use the equipment correctly.”
  • contact service / dealer p. 4
    “Do not attempt to wire the servo amplifier and servo motor until they have been installed. Otherwise, you may get an electric shock.”

This page summarises what the manufacturer’s manual says about AL.17; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.