Error codeSV0042
Feedback error 1 indicates a detector feedback signal pulse was omitted in the OHE-type/OHA-type detector used in a semiclosed loop system and ball screw end closed loop system. The manual lists no action for this code.
- Model
- Mitsubishi Electric 600M Series
- Display shows
- Feedback error 1 (SV0042)
- Type
- Error code
- Source
- Manual p. 469
What SV0042 means
Feedback error 1 p. 469
Common causes
- 1. A detector feedback signal pulse was omitted in the OHE-type/OHA-type detector used in a semiclosed loop system and ball screw end closed loop system. 2. A detector feedback signal pulse was omitted in the low-speed serial-type absolute position linear scale. p. 469
If SV0042 is still not resolved
This page summarises what the manufacturer’s manual says about SV0042; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.