Alarm codePR0061
The G60 command was used without uni-direction positioning specifications, which are required. The manual's first action is: “Check the specifications. Change the G60 program command to G00.”
- Model
- Mitsubishi Electric 600M Series
- Display shows
- No 1-direction positioning spec. (PR0061)
- Type
- Alarm code
- Source
- Manual p. 478
What PR0061 means
No 1-direction positioning spec. p. 478
Common causes
- The G60 command has been issued even though there is no uni-direction positioning specifications. p. 478
What to do
- Check the specifications. Change the G60 program command to G00. p. 478
Before you service the product, read the safety instructions in the manual p. 4.
If PR0061 is still not resolved
This page summarises what the manufacturer’s manual says about PR0061; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.