Mitsubishi Electric 600M Series Error OP0110: Invalid Research after NURBS

CNC milling machine · taken from the manufacturer’s manual, pages cited

Error codeOP0110

The block immediately after the NURBS interpolation mode was designated as the restart position, and the program was restarted. The manual's first action is: “Designate a block other than the block immediately after the NURBS mode as the restart position.”

Model
Mitsubishi Electric 600M Series
Display shows
Invalid Research after NURBS (OP0110)
Type
Error code
Source
Manual p. 476

What OP0110 means

Invalid Research after NURBS p. 476

Common causes

  • The block immediately after the NURBS interpolation mode was designated as the restart position, and the program was restarted. p. 476

What to do

  1. Designate a block other than the block immediately after the NURBS mode as the restart position. p. 476

Before you service the product, read the safety instructions in the manual p. 4.

If OP0110 is still not resolved

  • contact service / dealer p. 5
    “Do not change the fixed cycle program without prior consent from the machine manufacturer.”
  • contact service / dealer p. 5
    “Do not turn OFF the NC a”

This page summarises what the manufacturer’s manual says about OP0110; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.