There is an error in the communication between the NC and amplifier. The manual's first action is: “Check whether there is any abnormality in the following : • Cable (Are there any broken wires?) • Cable shield ground • Connector connections • Mounting state of the amplifier Contact the nearest service center.”
- Model
- Mitsubishi Electric 600M Series
- Display shows
- Aux axis commu err: Ax No/type illegal (AY0021)
- Type
- Error code
- Source
- Manual p. 495
What AY0021 means
Aux axis commu err: Ax No/type illegal p. 495
Common causes
- There is an error in the communication between the NC and amplifier. p. 495
What to do
- Check whether there is any abnormality in the following : • Cable (Are there any broken wires?) • Cable shield ground • Connector connections • Mounting state of the amplifier Contact the nearest service center. p. 495
Before you service the product, read the safety instructions in the manual p. 4.
If AY0021 is still not resolved
This page summarises what the manufacturer’s manual says about AY0021; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.