Merloni Various (e.g., F__7 C/P, FB97, FO87) Error F02: Temperature sensor disconnected or open circuit.

Oven · taken from the manufacturer’s manual, pages cited

Fault codeF02

The temperature sensor is disconnected or open circuited. The manual's first action is: “1. Check that the temperature probe is correctly connected to the terminals J9 and J10. 2. Substitute the temperature probe if its electrical resistance when empty exceeds 2 kW. 3. Substitute the electronic card (first the display one then the power one if the fault persists) re-using the previously substituted probe. After every operation execute procedure "A" to verify the positive outcome.”

Model
Merloni Various (e.g., F__7 C/P, FB97, FO87)
Display shows
Temperature sensor disconnected or open circuit. (F02)
Type
Fault code
Source
Manual p. 26

What F02 means

Temperature sensor disconnected or open circuit. p. 26

Common causes

  • Temperature sensor disconnected or open circuit. p. 26

What to do

  1. 1. Check that the temperature probe is correctly connected to the terminals J9 and J10. 2. Substitute the temperature probe if its electrical resistance when empty exceeds 2 kW. 3. Substitute the electronic card (first the display one then the power one if the fault persists) re-using the previously substituted probe. After every operation execute procedure "A" to verify the positive outcome. p. 26

Before you service the product, read the safety instructions in the manual p. 28.

If F02 is still not resolved

  • Substitute the display card. p. 28
    “Substitute the display card.”

This page summarises what the manufacturer’s manual says about F02; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Merloni. Found a mistake? Report an error.