Maxim DS21348/DS21Q348 Error BPV: E1/T1

Maxim DS21348/DS21Q348 · taken from the manufacturer’s manual, pages cited

Error codeBPV

BPV means two consecutive marks with the same polarity on E1/T1. The manual's first action is: “Will ignore BPVs due to HDB3 and B8ZS zero suppression when CCR2.3 = 0. Typically used with AMI coding (CCR2.3 = 1). ITU-T O.161.”

Model
Maxim DS21348/DS21Q348
Display shows
E1/T1 (BPV)
Type
Error code
Source
Manual p. 47

What BPV means

E1/T1 p. 47

Common causes

  • Two consecutive marks with the same polarity. p. 47

What to do

  1. Will ignore BPVs due to HDB3 and B8ZS zero suppression when CCR2.3 = 0. Typically used with AMI coding (CCR2.3 = 1). ITU-T O.161. p. 47

If BPV is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Maxim service.

This page summarises what the manufacturer’s manual says about BPV; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Maxim. Found a mistake? Report an error.