KOPPEL K5305-1V1 Error *59: Exit Error Report Code

Security system control panel · taken from the manufacturer’s manual, pages cited

Alarm code*59

Exit Error Report Code indicates an alarm sound when entry/exit or interior zone remains open after the Exit Delay time expires while system is armed. The manual's first action is: “If the system is not disarmed before the end of entry/exit or interior zone is still open, an "EXIT ALARM" message will be sent to the central station if an Exit Error Report code is entered. The keypad will display "EA" (Fixed-Word display keypads) or "EXIT ALARM" (Alpha display keypads), and alarm sounding will continue until the system is disarmed (or time occurs). An Exit Alarm condition will also result in a fault occurs in an exit or interior zone within 2 minutes following the end of the exit delay, and an "EXIT ALARM" message will be sent to the central station. With Contact ID format, the message will contain the zone number and error code 374 ("ALARM-EXIT ERROR").”

Model
KOPPEL K5305-1V1
Display shows
Exit Error Report Code (*59)
Type
Alarm code
Source
Manual p. 31

What *59 means

Exit Error Report Code p. 31

Common causes

  • If the system is armed and an entry/exit or interior zone is still open after the Exit Delay time has expired, an alarm will sound (keypad displays "EXIT ALARM"). If the system is disarmed before the end of the Entry Delay, the alarm sounding stops and no message is sent to the central station. The keypad will display "CA" (Fixed-Word display keypads) or "CANCELED ALARM" (Alpha display keypads). p. 31

What to do

  1. If the system is not disarmed before the end of entry/exit or interior zone is still open, an "EXIT ALARM" message will be sent to the central station if an Exit Error Report code is entered. The keypad will display "EA" (Fixed-Word display keypads) or "EXIT ALARM" (Alpha display keypads), and alarm sounding will continue until the system is disarmed (or time occurs). An Exit Alarm condition will also result in a fault occurs in an exit or interior zone within 2 minutes following the end of the exit delay, and an "EXIT ALARM" message will be sent to the central station. With Contact ID format, the message will contain the zone number and error code 374 ("ALARM-EXIT ERROR"). p. 31

Before you service the product, read the safety instructions in the manual p. 83.

If *59 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact KOPPEL service.

This page summarises what the manufacturer’s manual says about *59; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with KOPPEL. Found a mistake? Report an error.