Inovance IS300 Error Err17: (Contactor fault)

Servo driver · taken from the manufacturer’s manual, pages cited

Fault codeErr17

Err17 indicates a contactor fault condition. The manual's first action is: “Replace coil or contactor”

Model
Inovance IS300
Display shows
(Contactor fault) (Err17)
Type
Fault code
Source
Manual p. 22

What Err17 means

(Contactor fault) p. 22

Common causes

  • Is the contactor coil voltage normal? p. 22
  • Is the contactor coil functioning normally? p. 22
  • 1) Soft-start contactor not engaged p. 22
  • 2) Check if the contactor is effective; p. 22
  • 3) Seek manufacturer service. p. 22

What to do

  1. Replace coil or contactor p. 22
  2. Replace contactor p. 22
  3. 1) Check if the contactor cable is loose; p. 22
  4. 2) Check if the 24V power supply to the contactor has a fault; p. 22

Before you service the product, read the safety instructions in the manual p. 1.

If Err17 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.

This page summarises what the manufacturer’s manual says about Err17; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.