Error codeErr14
Err14 indicates a module overheat condition. The manual's first action is: “Check module temperature”
- Model
- Inovance IS300
- Display shows
- (Module overheat) (Err14)
- Type
- Error code
- Source
- Manual p. 21
What Err14 means
(Module overheat) p. 21
Common causes
- Is the module temperature too high? p. 21
- Is the heat sink temperature too high? p. 21
- Is the fan operating normally? p. 21
- Is the ambient temperature too high? p. 21
- 1) Frequency setting too high. p. 21
- 2) Fan damaged or airflow duct blocked. p. 21
- 3) Internal components of the servo drive damaged (thermocouple or others). p. 21
What to do
- Check module temperature p. 21
- Check heat sink temperature p. 21
- Check fan p. 21
- Check ambient temperature p. 21
- 1) Reduce frequency (FO-15). p. 21
- 2) Replace fan and clean airflow duct. p. 21
- 3) Seek manufacturer service. p. 21
Before you service the product, read the safety instructions in the manual p. 1.
If Err14 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Inovance service.
This page summarises what the manufacturer’s manual says about Err14; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.