45 on the Hitachi EH-150 is listed in the manual as: Overload error [periodic scan] [periodic processing]. The manual's first action is: “Stops *2”
- Model
- Hitachi EH-150
- Display shows
- Overload error [periodic scan] [periodic processing] (45)
- Type
- Error code
- Source
- Manual p. 430
What 45 means
Overload error [periodic scan] [periodic processing] p. 430
Common causes
- Execution time for periodic scan exceeded the execution period p. 430
What to do
- Stops *2 p. 430
- Change the program so that the periodic interrupt program execution time is shorter. p. 430
Before you service the product, read the safety instructions in the manual p. 3.
If 45 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Hitachi service.
This page summarises what the manufacturer’s manual says about 45; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Hitachi. Found a mistake? Report an error.