Overcurrent protection triggered due to ground faults at output terminals or during deceleration. The manual's first action is: “Remove the wires connected to the drive output terminals (U, V, and W) and perform a Megger test. SUGGESTED ACTIONS - Remove the short-circuit (including replacement of the wires, relay terminals and motor).”
- Model
- GE Fuji AF-300 Mini™
- Display shows
- Overcurrent protection (OC2)
- Type
- Fault code
- Source
- Manual p. 79
What OC2 means
Overcurrent protection p. 85
Common causes
What to do
- Remove the wires connected to the drive output terminals (U, V, and W) and perform a Megger test. SUGGESTED ACTIONS - Remove the short-circuit (including replacement of the wires, relay terminals and motor). p. 85
- Stops the motor to protect drive from an overcurrent due to a short-circuit in the output circuit. p. 85
Before you service the product, read the safety instructions in the manual p. 4.
If OC2 is still not resolved
This page summarises what the manufacturer’s manual says about OC2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with GE Fuji. Found a mistake? Report an error.