Operation protection activated when key was pressed with H66 set to 1 or 3, or start check function activated with H66 set to 2 or 3. The manual's first action is: “CHECK Change the setting for H66 so that the STOP key priority function is invalid to ensure that the drive does not operate unexpectedly.”
- Model
- GE Fuji AF-300 Mini™
- Display shows
- Operation protection (Er6)
- Type
- Error code
- Source
- Manual p. 79
What Er6 means
Operation protection p. 93
Common causes
- The key was pressed when H66 = 1 or 3. p. 93
- The start check function was activated when H66 = 2 or 3. p. 93
What to do
- CHECK Change the setting for H66 so that the STOP key priority function is invalid to ensure that the drive does not operate unexpectedly. p. 93
- CHECK Check that Er6 occurs when: – The power is switched ON. – An alarm is released (the key is pressed) – The link command (LE) has switched the drive operations. SUGGESTED ACTIONS – Reconsider the running sequence to avoid input of the run command when Er6 has occurred. – Change the setting for H66 so that the STOP key priority function is invalid to ensure the drive does not operate unexpectedly. (To reset the alarm, turn the run command off.) p. 93
Before you service the product, read the safety instructions in the manual p. 4.
If Er6 is still not resolved
This page summarises what the manufacturer’s manual says about Er6; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with GE Fuji. Found a mistake? Report an error.